Kontaktorius 15kW LC1D323BD TeSys Deca, 3P(3NO), AC-3/AC-3e, <=440V, 32A, 24V DC ritė, spyruokliniai kontaktai
-
Kodas: 080777Kaina 4963€ be PVM(60 05 € su PVM)Likutis: 2 vnt.GamintojasSchneider Electric
-
Range of product
TeSys D
Product or component type
Contactor
Device short name
LC1D
Contactor application
Motor control
Resistive load
Utilisation category
AC-1
AC-3
Poles description
3P
Pole contact composition
3 NO
[Ue] rated operational voltage
<= 690 V AC 25...400 Hz for power circuit
<= 690 V DC for power circuit
[Ie] rated operational current
32 A (<= 60 °C) at <= 440 V AC AC-3 for power
circuit
50 A (<= 60 °C) at <= 440 V AC AC-1 for power
circuit
Motor power kW
15 kW at 380...400 V AC 50/60 Hz
7.5 kW at 220...230 V AC 50/60 Hz
18.5 kW at 500 V AC 50/60 Hz
18.5 kW at 660...690 V AC 50/60 Hz
15 kW at 415...440 V AC 50/60 Hz
Motor power hp
2 hp at 115 V AC 50/60 Hz for 1 phase motors
5 hp at 230/240 V AC 50/60 Hz for 1 phase motors
7.5 hp at 200/208 V AC 50/60 Hz for 3 phases
motors
10 hp at 230/240 V AC 50/60 Hz for 3 phases
motors
20 hp at 460/480 V AC 50/60 Hz for 3 phases
motors
30 hp at 575/600 V AC 50/60 Hz for 3 phases
motors
Control circuit type
DC standard
Control circuit voltage
24 V DC
Auxiliary contact composition
1 NO + 1 NC
[Uimp] rated impulse withstand
voltage
6 kV conforming to IEC 60947
Overvoltage category
III
[Ith] conventional free air thermal
current
50 A at <= 60 °C for power circuit
10 A at <= 60 °C for signalling circuit
Irms rated making capacity
550 A at 440 V for power circuit conforming to IEC
60947
140 A AC for signalling circuit conforming to IEC
60947-5-1
250 A DC for signalling circuit conforming to IEC
60947-5-1
Rated breaking capacity
550 A at 440 V for power circuit conforming to IEC
60947
[Icw] rated short-time withstand
current
138 A <= 40 °C 1 min power circuit
260 A <= 40 °C 10 s power circuit
430 A <= 40 °C 1 s power circuit
60 A <= 40 °C 10 min power circuit
100 A 1 s signalling circuit
120 A 500 ms signalling circuit
140 A 100 ms signalling circuit
Associated fuse rating
63 A gG at <= 690 V coordination type 1 for power
circuit
63 A gG at <= 690 V coordination type 2 for power
circuit
10 A gG for signalling circuit conforming to IEC
60947-5-1
The information provided in this documentation contains general descriptions and/or technical characteristics of the performance of the products contained herein.
This documentation is not intended as a substitute for and is not to be used for determining suitability or reliability of these products for specific user applications.
It is the duty of any such user or integrator to perform the appropriate and complete risk analysis, evaluation and testing of the products with respect to the relevant specific application or use thereof.
Neither Schneider Electric Industries SAS nor any of its affiliates or subsidiaries shall be responsible or liable for misuse of the information contained herein.
1 / 3
Average impedance 2 mOhm at 50 Hz - Ith 50 A for power circuit
[Ui] rated insulation voltage 600 V for power circuit certifications CSA
600 V for power circuit certifications UL
690 V for power circuit conforming to IEC 60947-4
1
690 V for signalling circuit conforming to IEC
60947-1
600 V for signalling circuit certifications CSA
600 V for signalling circuit certifications UL
Power dissipation per pole 2 W AC-3
5 W AC-1
Protective cover With
Mounting support Plate
Rail
Standards EN 60947-4-1
EN 60947-5-1
IEC 60947-4-1
IEC 60947-5-1
UL 508
CSA C22.2 n°14
Product certifications BV
CCC
CSA
DNV
GL
GOST
RINA
UL
LROS
Connections - terminals Control circuit: screw clamp terminals 1 cable(s)
1...4 mm² - cable stiffness: flexible - without cable
end
Control circuit: screw clamp terminals 2 cable(s)
1...4 mm² - cable stiffness: flexible - without cable
end
Control circuit: screw clamp terminals 1 cable(s)
1...4 mm² - cable stiffness: flexible - with cable end
Control circuit: screw clamp terminals 2 cable(s)
1...2.5 mm² - cable stiffness: flexible - with cable
end
Control circuit: screw clamp terminals 1 cable(s)
1...4 mm² - cable stiffness: solid - without cable
end
Control circuit: screw clamp terminals 2 cable(s)
1...4 mm² - cable stiffness: solid - without cable
end
Power circuit: screw clamp terminals 1 cable(s)
2.5...10 mm² - cable stiffness: flexible - without
cable end
Power circuit: screw clamp terminals 2 cable(s)
2.5...10 mm² - cable stiffness: flexible - without
cable end
Power circuit: screw clamp terminals 1 cable(s)
1...10 mm² - cable stiffness: flexible - with cable
end
Power circuit: screw clamp terminals 2 cable(s)
1.5...6 mm² - cable stiffness: flexible - with cable
end
Power circuit: screw clamp terminals 1 cable(s)
1.5...10 mm² - cable stiffness: solid - without cable
end
Power circuit: screw clamp terminals 2 cable(s)
2.5...10 mm² - cable stiffness: solid - without cable
end
Tightening torque Control circuit: 1.7 N.m - on screw clamp
terminals - with screwdriver flat Ø 6 mm
Control circuit: 1.7 N.m - on screw clamp
terminals - with screwdriver Philips No 2
Power circuit: 2.5 N.m - on screw clamp terminals - with screwdriver flat Ø 6 mm
Power circuit: 2.5 N.m - on screw clamp terminals - with screwdriver Philips No 2
Operating time 53.55...72.45 ms closing
16...24 ms opening
Safety reliability level B10d = 1369863 cycles contactor with nominal
load conforming to EN/ISO 13849-1